QKM6E-250

Smart circuit breaker for 400V, 100A–630A systems, offering comprehensive protection and remote control. Features multi-parameter measurement, RS-485/Bluetooth/HPLC connectivity, and a hot-swappable controller. Compliant with GB/T 14048.2, DL/T645, DL/T 698.45.

Share to:

Product Overview

This circuit breaker is suitable for AC 50Hz power systems with rated voltage up to 400V and rated current from 100A to 630A. It is used to distribute electrical energy and protect lines and power equipment from overload, short circuit, undervoltage, overvoltage, and phase loss faults. It can also be used to control infrequent operation of motors.

This product features current, voltage, power, and electrical quantity measurement; an RS-485 interface; a power line carrier module; Bluetooth wireless communication; and an HPLC pluggable module interface. The product complies with DL/T645 and DL/T-698.45 communication protocols, enabling remote signaling, remote measurement, remote adjustment, and remote tripping functions. It has linkage protection functions and temperature monitoring protection for incoming and outgoing terminals. The controller is hot-swappable, allowing for direct removal of the controller module for maintenance or replacement without disassembling the switch while the circuit is energized. Removing the controller does not affect the normal operation of the switch, ensuring the normal functioning of the three-stage protection.

Complies with the following standard: GB/T14048.2 <>

Main Technical Parameters

Product ModelQKM□E-250QKM□E-400QKM□E-630
Frame Size Rated Current Inm (A)250A400A630A
Applicable Poles3P3P3P
Rated Operating Voltage Ue (V)AC400 / 50HzAC400 / 50HzAC400 / 50Hz
Rated Insulation Voltage Ui (V)100010001000
Rated Impulse Withstand Voltage Uimp (kV)81212
Rated Ultimate Short-Circuit Breaking Capacity Icu (kA)L: 20
S: 35
M: 50
H: 85
L: 25
S: 35
M: 65
H: 100
L: 35
S: 50
M: 65
H: 100
Rated Service Short-Circuit Breaking Capacity Ics (kA)L: 15
S: 35
M: 35
H: 70
L: 20
S: 35
M: 50
H: 75
L: 25
S: 35
M: 50
H: 70
Rated Short-Time Withstand Current Icw (kA / 1s)51010
Arc Distance (Upper / Lower) mm50 / 0100 / 0100 / 0
Rated Current In (A)100A–250A Adjustable160A–400A Adjustable—
Overload Delay Time Factor (s)3 – 18 Adjustable3 – 18 Adjustable3 – 18 Adjustable
Short-Time Delay Multiple (×In)2 – 10 Adjustable2 – 10 Adjustable2 – 10 Adjustable
Short-Time Delay Time (ms)30 – 600 Continuously Adjustable30 – 600 Continuously Adjustable30 – 600 Continuously Adjustable
Instantaneous Trip Multiple (×In)4 – 12 Adjustable4 – 12 Adjustable4 – 12 Adjustable
Overvoltage Trip Value (V)Default 275 ±1% (User Adjustable)Default 275 ±1% (User Adjustable)Default 275 ±1% (User Adjustable)
Undervoltage Trip Value (V)Default 165 ±1% (User Adjustable)Default 165 ±1% (User Adjustable)Default 165 ±1% (User Adjustable)
Phase-Loss Trip Value (V)Default 120 ±1% (User Adjustable)Default 120 ±1% (User Adjustable)Default 120 ±1% (User Adjustable)
Product Usage CategoryClass AClass BClass B