QYW6 series plastic-case circuit breaker

Intelligent universal circuit breaker with optimized dimensions, enhanced built-in communication and measurement functions, and diverse installation configurations. Features an intelligent, user-friendly interface and effortless operation. Integrated with closing-ready electrical indication, electric closing, and remote reset functions, plus mechanical closing-ready indication and error energy storage safety protection for enhanced functional safety.

Share to:

Product Overview

The QYW6 intelligent universal circuit breaker is engineered with a design philosophy of continuous innovation and performance leap. It features optimized overall dimensions, enhanced built-in communication and measurement functions, and supports diverse installation configurations. Boasting an intelligent and user-friendly interface combined with effortless operation, it embodies the cutting-edge quality of modern electrical products.

The circuit breaker is integrated with closing ready electrical indication, electric closing, and remote reset functions. It is also equipped with mechanical indication for the closing ready state of the operating mechanism and an error energy storage safety protection device, further enriching its functional safety features.

Core Performance Advantages

  1. Full Compatibility & Expansion: Retains all functions of the QKW7 series while introducing additional functions and wiring methods.
  2. Precision Protection System: The on-board controller features a “dual-adjustment” protection system (adjustable via both knobs and LCD touch keys).
  3. High-Performance Processing: Adopts a 16-bit DSP high-performance digital signal processor.
  4. Enhanced Anti-Interference & Accuracy: 12-bit ADC ensures a measurement accuracy of up to 1/2000.
  5. Ultra-Low Power Consumption: Reduced from 3W to 1.5W.
  6. Dual Watchdog Technology (WDT): Ensures stable and reliable operation of the control system.
  7. Integrated Power Supply: Built-in AC power module for simplified wiring.

Upgraded Structural Features

  • Advanced Controller: Added drawer communication module and short message notification module for smart operation.
  • Expanded Secondary Circuit: Increased terminal ports to meet customized project requirements.
    • 2500A~4000A models: 90 ports (vs. 47 ports for QKW7 2000~6300).
  • High-Capacity Auxiliary Switches: Contact capacity up to 830VA, configurable with up to 6 NO and 6 NC contacts (with or without a common port).
  • Universal Release Design: Undervoltage release, shunt release, and closing electromagnet feature a universal external dimension across the entire series. The undervoltage time-delay release supports adjustable delay time and undervoltage delay time.

Reliable Drawer Mechanism

  • Three-position interlocking structure (Connect, Test, Isolate).
  • Pointer-type three-position display for intuitive status identification.
  • Three-position rotary locking structure for secure operation.
  • Middle-position draw-out mechanism for smooth maintenance.
  • Safety single-point opening structure to prevent misoperation.

Technical Specifications

ItemQYW6-2500QYW6-4000
Rated Insulation Voltage Ui (V)12501250
Rated Impulse Withstand Voltage Uimp (kV)1212
Frame Grade Rated Current Inm (A)25004000
Rated Current In (A)630, 800, 1000, 1250, 1600, 2000, 25002000, 2500, 2900, 3200, 3600, 4000
Rated Ultimate Short-Circuit Breaking Capacity Icu (kA)
1000/1140V6060
690/800V7070
Rated Operational Short-Circuit Breaking Capacity Ics (kA)
1000/1140V6060
690/800V7070
Rated Short-Time Withstand Current Icw (kA 1s/0.5s)
1000/1140V6060
690/800V7070
Breaking Time (No Additional Delay) (ms)10~2010~20
Closing Time (ms)<60<60
Operational Performance
Operating Cycles (Service Life) – Mechanical75006500
Operating Cycles (Service Life) – Electrical50002000
Total125008500
Dimensions & Weight
W × H × D (mm) (Width × Height × Depth)
3P Drawer-type347 × 450 × 406.5440 × 450 × 406.5
4P Drawer-type442 × 450 × 406.5566 × 450 × 406.5
3P Fixed-type368 × 415.5 × 308461 × 415.5 × 308
4P Fixed-type463 × 415.5 × 308587 × 415.5 × 308
Weight (kg) (Net / Gross)
3P Drawer-type98/107120/131
4P Drawer-type120/131148/160
3P Fixed-type45/5455/66
4P Fixed-type55/6668/80
Intelligent Controller Type3H, 3M, 2H, 2M, M3H, 3M, 2H, 2M, M

Intelligent Controller Technical Specifications

Feature Item3H3M2H2MM
Auxiliary Power Supply Voltage
220V AC○○○○○
380V AC○○○○○
90-300V DC○○○○○
50V AC (70V DC) – 480V AC (650V DC)○○○○○
AC200-AC450 Universal○○○○○
24V DC○○○○○
48V DC○○○○○
Other voltages can be customized○○○○○
HMI
LED current bar–––––
Digital tube + LED––✓✓✓
Segment LCD–––––
Chinese dot-matrix LCD + LED✓✓–––
Button operation✓✓✓✓✓
Rotary switch + button–––––
Language: Chinese/English✓✓–––
Communication Functions
Modbus-RTU✓–✓––
Profibus-DP○–○––
HPLC (DL/T 645)○––––
WiFi○–○––
DeviceNET○–○––
CAN○–○––
Ethernet○–○––
ProfiNET○–○––
IEC61850○–○––
Bluetooth○–○––
4G-LTE○–○––
Protection Functions
Long-time overcurrent protection (multiple curves selectable)✓✓✓✓✓
Short-time delay overcurrent protection (multiple curves selectable)✓✓✓✓✓
Instantaneous overcurrent protection✓✓✓✓✓
Current unbalance (phase failure) protection✓✓✓✓–
Earth fault protection (differential/current type, one of two)✓✓✓✓✓
Residual current protection (IΔn)○○○○○
Neutral overcurrent protection (3P+N and 4P only)○○○○○
Overload pre-alarm✓✓––○
MCR (Making current protection)✓✓○○○
HSISC (High-set instantaneous protection)✓✓○○○
Overvoltage protection (disabled by default)✓✓–––

Product Diagram

image

Function Comparison Table

Feature CategoryItem3H3M2H2MM
ProtectionUndervoltage Protection (Default OFF)✔✔–––
Overvoltage Protection (Default OFF)✔✔–––
Overcurrent Protection (Default OFF)✔✔–––
Phase Loss Protection✔✔–––
Phase Sequence Protection (Default OFF)✔✔–––
Residual Current Protection (Default OFF)✔✔–––
Load Monitoring✔✔✔✔✔
Regional Monitoring○○○○–
Overload Alarm○○–––
Busbar / Cable Temperature Protection○○○○○
Load Shedding Control–✔✔✔–
Demand (Energy) Management○○––○
Measurement – CurrentThree-phase Current, Phase Current, Unbalance✔✔✔✔✔
Neutral Current○○○○○
Measurement – VoltageLine Voltage, Phase Voltage, Unbalance✔○✔○–
Frequency✔✔✔○–
Power & EnergyActive Power✔✔✔○–
Reactive Power✔✔–––
Power Factor✔✔✔○–
Energy (Active / Reactive / Apparent)✔✔–––
Power QualityHarmonics✔✔–––
Waveform Capture✔✔–––
Demand Measurement○○–––
System Time✔✔○○–
Long-term Energy Statistics✔✔–––
Control & MaintenanceSelf-test (Overheat, Memory, A/D Sampling)✔✔✔✔✔
Remote Control✔✔✔✔✔
Key Lock✔✔✔✔✔
I/O Fault Alarm Output○○○○–
Contact Output✔✔✔✔–
Records & CommunicationTrip Records101010108
Alarm Records1010–––
Fault Records1010–––
4-channel Relay Output○○○○○
Data Interface / Communication Port✔✔✔✔✔

Legend:

✓= Standard

○ = Optional

– = Not Available

Controller Accessories

DC Power Supply Module (Optional)

image

When the supply voltage is DC220V or DC110V, an external dedicated power module is required for the intelligent controller.
The module is designed for 35mm standard DIN rail mounting.

Specifications

ItemSpecification
Input VoltageDC220V ±15% or DC110V ±15%
Output VoltageDC24V ±5%
Output Current1.5A

Overall Dimensions

image

Refer to the “Circuit Breaker & Current Transformer Wiring Diagram” section for connection diagrams.

External (N-type) Current Transformer

image

Description

  • External (N-type) current transformer (equipped with 3P+N function).
  • For special site requirements, users may install an external CT on each phase conductor (3P+N). Corresponding CT ratio and installation method must be configured accordingly.
  • Users should provide installation brackets as required.
  • Recommended distance between CT and breaker: ≤ 2 meters.

Installation and Overall Dimensions

image

Refer to the “Circuit Breaker & Current Transformer Wiring Diagram” section for connection diagrams.

Ground Fault Transformer

image

Ground Fault Transformer (Zero-Sequence Protection)

When the grounding method is zero-sequence grounding, an external dedicated zero-sequence current transformer can be used to detect grounding current in the cable.
Installation can be carried out upstream or downstream of the breaker.
Recommended distance between transformer and breaker: ≤ 10 meters.

Leakage Current Transformer

image

Used for leakage protection applications.
When grounding is achieved through leakage current detection, an external dedicated leakage current transformer is required.
Recommended installation distance between transformer and breaker: ≤ 2 meters.

Communication Accessories

Optional accessories include:

  • Communication software
  • Data concentrator
  • Communication module (plug-in or built-in type)
  • Data transfer unit
  • Maintenance module
  • Power supply module
  • Dedicated communication cable

(For detailed specifications, please refer to the corresponding accessory documentation.)

Communication Architecture & Network Diagram

image

Communication Structure Diagram

① Built-in Communication Module

② Micro Switch
    (Closing / Opening Coil, Fault Trip, Closing Ready, Energy Storage Status)

③ Closing and Opening Coils

④ Closing, Test, and Disconnected Position Signals

⑤ Plug-in Communication Module

COM Communication Options

For fixed-type circuit breaker communication, the COM module is composed of the internal communication module of the circuit breaker, together with a series of auxiliary contact signals (opening/closing coil, fault trip, closing ready, energy storage status). It also connects to the closing and opening coils with communication functionality.

For draw-out type circuit breaker communication, the COM configuration includes:

  • Installation position signals (connected, test, disconnected)
  • Opening/closing coils
  • Fault trip
  • Closing ready
  • Energy storage status

It also provides connections for communication-enabled closing and opening coils.

Additionally, an external draw-out communication module is required. This module provides position signals (connected, test, disconnected) through a three-position auxiliary switch mounted on the cradle.

The COM circuit breaker status indicators are independent from the breaker’s local indicator contacts. The breaker’s indication contacts remain effective even if the COM module is not installed.

Built-in Communication Module

This module is integrated into the control unit and installed at the rear of the control unit. It is responsible for transmitting and receiving communication signals from the network.

A flexible cable connects the control unit and the communication module for data transmission.

The module operates with DC24V power supply.

Draw-out Communication Module

This is an external module. When the circuit breaker is in the open position, the module allows address setting for the cradle and stores the assigned address.

The module operates with DC24V power supply.

Communication Coils (Closing & Opening)

The communication-enabled closing and opening coils are connected to the built-in communication module.

The remote trip function (second opening coil or undervoltage release) operates independently of the communication accessories and cannot be connected to the built-in communication module.

image

CONTACT FOR FREE SAMPLE

Scroll to Top

Request a Technical Quote

Technical Tip: For guaranteed form delivery, we recommend disabling Private/Incognito mode.